home

table 1

flow charts

 

GRADE

FILTRATION RANGE
NOMINAL FILTRATION
U.S. STD. SCREEN
(Approximate)
PRACTICAL MINIMUM THICKNESS INCHES
TENSILE STRENGTH PSI*
PRESSURE DROP RATIO**
INCHES
MICRONS
INCHES MICRONS
12
.007 TO .012
180-300
.010
250
80-50
.188
2,000
1
23
.005 TO .007
128-180
.006
150
120-80
.125
3,000
2
34
.002 TO .005
51-128
.0035
90
270-100
.090
4,000
4
46
.001 TO .002
26-51
.0015
40
400-270
.060
5,000
8
68
.0008 TO .0018
21-45
.0014
35
-400
.050
5,000
10
83
.0006 TO .0012
16-32
.001
25
NA
.040
6,000
24
103
.0005 TO .001
13-26
.0008
20
NA
.040
6,000
40
153
.00025 TO .0005
7-13
.0004
10
NA
.040
7,000
80

   *Tensile strength of new pre-alloyed material grades will deviate from this table.
   **Shows approximate relationship between pressure dorp and grade of material for a given area, thickness and flow. Directly proportional relationship exists with increased thickness. Inversely proportional relationship exists with increased area.